© Baxi Heating U.K. Limited 2009.
5110945/07
Model 347
Black Beauty 4 Oxysafe
RADIANT / CONVECTOR GAS FIRE
(G.C. No. 32-032-62)
INSTALLER: Please leave this guide with the owner
INSTALLATION AND OWNER GUIDE
We trust that this guide gives
sufficient details to enable this
appliance to be installed and
maintained satisfactorily. However, if
further information is required, our
Valor Fires Technical Helpline will
be pleased to help.
Telephone 0844 8711 565 (National
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone 0044 844 8711 565.
Vista de pagina 0
1 2 3 4 5 6 ... 43 44

Indice de contenidos

Pagina 1 - Black Beauty 4 Oxysafe

© Baxi Heating U.K. Limited 2009.5110945/07Model 347Black Beauty 4 OxysafeRADIANT / CONVECTOR GAS FIRE(G.C. No. 32-032-62)INSTALLER: Please leave this

Pagina 2

b) All relevant national and local rules in force.c) The current building regulations.Where no specific instructions are given, reference should be ma

Pagina 3

4.6 Fireplace preparation.4.6.1 The appliance can be fitted to a purpose made proprietary class “O” 150°Csurround.4.6.2 If the fireplace opening is

Pagina 4

4.7 Fireplace clearances.4.7.1 The minimum allowable distance from the outside of the appliance fascia to acorner wall having combustible material or

Pagina 5

4.8 The Flue spigot.4.8.1 The flue spigot and any spigot extension must be capable of passing throughthe closure plate by at least 38mm with a minimum

Pagina 6

4.9. The hearth.The appliance must be mounted on a non-combustible hearth except when theconditions in section 4.10.3 are met (N.B. conglomerate marbl

Pagina 7

The fireplace opening must be within the following dimensions:(a)The total height of the closure plate is 660mm and will accommodate a maximumopening

Pagina 8

4.10.4 Metal flue box.The appliance can be installed to a metal flue box conforming to BS 715 Section 6(For gas fires to BS 7977-1) having a minimum i

Pagina 9

accordance with BS 5440 Part 1 to ensure that the products of combustion can besafely dispersed into the outside atmosphere. Where the appliance is co

Pagina 10 - INSTALLER GUIDE

10. If the fire is fitted to a recessed fireplace, an extension flue spigot up to amaximum total length of 125mm may be used. The extension must be a

Pagina 11

5.4.1 Hearth mounting.(See figure 8).The closure plate must be fitted and sealed tothe hearth and fireplace opening using asuitable heat resistant mat

Pagina 12

Baxi Heating U.K. Limited 2009.All rights reserved. No part of this publication may be reproduced in any material form(including photocopying), stored

Pagina 13

6. APPLIANCE INSTALLATION6.1 Installing to a hearth.1. Place the fire centrally on the hearth making sure that the spigot lines up with thespigot hol

Pagina 14

6.5 Flue restrictor adjustment.(See figure 11).The appliance has an integral adjustable flue draught restrictor. This is supplied set inthe fully open

Pagina 15

7. CONTROL AND PRESSURE CHECKS7.1 Optional special needs control.1. The fire is supplied with a ‘special needs control’ that users with impaired dexte

Pagina 16

The valve is located in the body of the tap. The valve should operate within 60seconds of the pilot going out. If the valve does not operate within th

Pagina 17

9. SPILLAGE CHECK1. Close all doors and windows in the room containing the fire.2. Light the appliance and set the control knob to the maximum positi

Pagina 18

10. FINAL REVIEW COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTION OF THE OWNER GUIDE (See last pages of the OWNER guide). Make sure tha

Pagina 19

11. SERVICING AND PARTS REPLACEMENT Always turn off the gas supply and allow the appliance to cool completelybefore commencing any servicing (The ap

Pagina 20

 Replace the dress guard. Locate the bottom of the dress guard in the two holes inthe bottom panel apron. Push the guard back so that the two spring

Pagina 21

11.5 To remove the complete burner module, pipes and pilot.1. Remove the fascia as section 11.2.2. Support the inlet ‘T’ connector to avoid straining

Pagina 22

Page 29© Baxi Heating U.K. Limited 2009.OWNER GUIDEOWNER GUIDEFOR WARRANTY AND SERVICE INFORMATIONSEE PAGES 38 TO 43

Pagina 23

Safety First.Valor Fires fires are CE Approved and designed to meet the appropriate BritishStandards and Safety Marks.Quality and Excellence.All Valor

Pagina 24

LIST OF CONTENTSSection PageSAFETY 31GAS CONSUMPTION 32APPLIANCE DIMENSIONS 33OPERATING YOUR FIRE 33The Oxysafe flame sensing and flue blockage saf

Pagina 25

SAFETYDo have the fire installed by a competent person. In the United Kingdom, installationmust be in accordance with the latest edition of the Gas Sa

Pagina 26

Do get advice about the suitability of any wall covering near your fire. Soft wallcoverings (e.g. embossed vinyl, etc.) which have a raised pattern ar

Pagina 27

APPLIANCE DIMENSIONSOPERATING YOUR FIREThe Oxysafe flame sensing and flue blockage safety system.For your safety, this appliance is fitted with a flue

Pagina 28

To light the fire.The control is shown in figure 3.Depress the control knob and slowly turnanticlockwise towards the 1 position. A sparkshould be gene

Pagina 29 - OWNER GUIDE

Lighting with a match or taper.Depress the control knob and turnanticlockwise towards the 1 position.While keeping the knob depressed, light thepilot

Pagina 30

REPLACING THE RADIANTS(See figure 5).Always use the correct type of replacement radiant. Ask for Valor Fires partnumber 5132071 (Single Radiant).Turn

Pagina 31

MAINTENANCERegular maintenance.In order to achieve and maintain high levels of personal safety and performanceefficiency, it is essential that the ope

Pagina 32

WARRANTY AND SERVICEStandard Warranty Terms & ConditionsThe warranty is for 12 months subject to contract.In the United Kingdom servicing can be c

Pagina 33

When calling heateam, it would be helpful if you could have the following informationto hand:-1. Fire serial number and fascia code (The serial number

Pagina 34

Page 4© Baxi Heating U.K. Limited 2009.INSTALLER GUIDEFOR OWNER GUIDE SEE PAGES 29 TO 43INSTALLER GUIDE

Pagina 35

© Baxi Heating U.K. Limited 2009.Page 40OWNER GUIDE

Pagina 36

Page 41© Baxi Heating U.K. Limited 2009.OWNER GUIDE

Pagina 37

Page 42© Baxi Heating U.K. Limited 2009.To be completed by installer:Installer Details (Block Capitals)Installer NameGas Safe Register or CorgiRegistr

Pagina 38

Page 43© Baxi Heating U.K. Limited 2009.Figure 6.Brand (Please tick)Baxi Valor Wonderfire Other...D D M M Y YDate of Installat

Pagina 39

© Baxi Heating U.K. Limited 2009.

Pagina 40

CONTENTSSection heading PageINSTALLER GUIDE 4 - 28OWNER GUIDE 29 - 431. SAFETY 72. LIST OF ACCESSORIES 73. APPLIANCE DATA AND EFFICIENCY 83.1 A

Pagina 41

7. CONTROL AND PRESSURE CHECKS 227.1 Optional special needs control. 227.2 Check control settings. 227.3 Flame supervision and spillage monitoring

Pagina 42

1. SAFETYInstallerBefore continuing any further with the installation of this appliance please read thefollowing guide to manual handling: The lifti

Pagina 43

3. APPLIANCE DATA AND EFFICIENCY3.1 Appliance data.The appliance information label is on the inner face of the back panel at the lower lefthand side

Pagina 44

4. GENERAL INSTALLATION REQUIREMENTS4.1 Regulations, Standards and Law.The installation must be in accordance with these instructions.For the user’s